9..3 Command Reference
GOTOGOTO
GOTOGOTO
GOTO
ClassificationClassification
ClassificationClassification
Classification: executing keyword
a)a)
a)a)
a)
As starting keywordAs starting keyword
As starting keywordAs starting keyword
As starting keyword, every executor that follows after the GOTO will try to
go directly to a givengo directly to a given
go directly to a givengo directly to a given
go directly to a given
step.step.
step.step.
step.
GOTO [CUE] [W] [EXEC X] [FADE Y] [DELAY Z] [ENTER]GOTO [CUE] [W] [EXEC X] [FADE Y] [DELAY Z] [ENTER]
GOTO [CUE] [W] [EXEC X] [FADE Y] [DELAY Z] [ENTER]GOTO [CUE] [W] [EXEC X] [FADE Y] [DELAY Z] [ENTER]
GOTO [CUE] [W] [EXEC X] [FADE Y] [DELAY Z] [ENTER]
Giving the keyword CUE is optional.
If W (cue number) is not given, you will be prompted for it.
If executor is not given, default executor will be used.
If fade or delay are given, they overwrite the default GOTO times.
The default GOTO times can be changed in the SETUP / DEFAULTS menu.
b)b)
b)b)
b)
In an assign commandIn an assign command
In an assign commandIn an assign command
In an assign command, this function can be put on an executor button (see ASSIGN).
In fact you will end up with an LOAD assigned to the executor button, because it has to ask for the cue anyway.
GROUPGROUP
GROUPGROUP
GROUP
ClassificationClassification
ClassificationClassification
Classification: object keyword
a)a)
a)a)
a)
as starting keyword:as starting keyword:
as starting keyword:as starting keyword:
as starting keyword:
GROUP ENTER
GROUP becomes the DEFAULT KEYWORD.
GROUP (range list) ENTER
Select groups in range list.
GROUP (range list) AT  (see AT)
Apply values to groups in range list.
Group numbers in the range list must be in the interval [ 1  999].
b)b)
b)b)
b)
as target for the following executing commands:as target for the following executing commands:
as target for the following executing commands:as target for the following executing commands:
as target for the following executing commands:
ON activate devices contained in group.
OFF deactivate and deselect devices contained in group.
PAUSE PARK all devices of group.
GO UNPARK all devices of group.
IFIF
IFIF
IF
ClassificationClassification
ClassificationClassification
Classification: helping keyword
IFIF
IFIF
IF is performing a logical AND within selections. It is never enlarging the current selection. It leaves only those
devices selected which are included in to different selections:
Assuming that we have two groups (we will use real names to make it clearer):
PAR64 includes ALL PAR64 lamps
FRONT_TRUSS includes ALL lamps on the front truss.
PAR64 IF FRONT_TRUSS ENTERPAR64 IF FRONT_TRUSS ENTER
PAR64 IF FRONT_TRUSS ENTERPAR64 IF FRONT_TRUSS ENTER
PAR64 IF FRONT_TRUSS ENTER will therefore select all PAR64 which are on the front truss !
General Syntax:
[ (selection1) ] IF (selection2) ENTER[ (selection1) ] IF (selection2) ENTER
[ (selection1) ] IF (selection2) ENTER[ (selection1) ] IF (selection2) ENTER
[ (selection1) ] IF (selection2) ENTER
If selection1 is not given, the current selection will be used.
IFOUTPUTIFOUTPUT
IFOUTPUTIFOUTPUT
IFOUTPUT
ClassificationClassification
ClassificationClassification
Classification: operational keyword
IFOUTPUT IFOUTPUT
IFOUTPUT IFOUTPUT
IFOUTPUT is selecting devices depending on the current stage output.
General syntax:
IFOUTPUT (object list) [ENTER]IFOUTPUT (object list) [ENTER]
IFOUTPUT (object list) [ENTER]IFOUTPUT (object list) [ENTER]
IFOUTPUT (object list) [ENTER]
If the object list is a hit on an executor´s button, or a click into an object pool window, ENTER is not needed.
Examples:
IFOUTPUT EXEC 1 ENTERIFOUTPUT EXEC 1 ENTER
IFOUTPUT EXEC 1 ENTERIFOUTPUT EXEC 1 ENTER
IFOUTPUT EXEC 1 ENTER All devices which have stage output from executor 1 will be selected.
IFOUTPUT PRESET 1.1 ENTERIFOUTPUT PRESET 1.1 ENTER
IFOUTPUT PRESET 1.1 ENTERIFOUTPUT PRESET 1.1 ENTER
IFOUTPUT PRESET 1.1 ENTER All devices which have the preset 1.1 active on stage will become selected.
Very nice for selecting all fixtures that have a blue star currently on stage.