Page 2
©
2012 Sargent and Greenleaf
SARGENT AND GREENLEAF
®
A Subsidiary of Stanley Security Solutions, Inc.
Revision date: 9/19/2012
Electronic Lock Features Chart
UL Listed Type 1
✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔
CEN B
✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔
VdS Class 2
✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔
A2P B/E
✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔
DNV 3492
✔ ✔ ✔ ✔ ✔ ✔
Multiple User Mode
✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔
Dual User Mode
✔
CHANGEABLE
TO DUAL USER
MODE
✔
CHANGEABLE
TO DUAL USER
MODE
✔ ✔ ✔ ✔ ✔ ✔
Manager/Employee
Mode
✔
INCLUDED WITH
MULTIPLE USER
CONFIGURATION
INCLUDED WITH
MULTIPLE USER
CONFIGURATION
✔ ✔ ✔ ✔ ✔
Management Reset
Code (MRC)
✔ ✔ ✔ ✔
ORDER 6126-146 ORDER 6127-246
Programmer Code
✔ ✔ ✔ ✔ ✔
Master Code
✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔
Officer Code(s)
2 2
Administrator Code(s)
4 4
Manager Code
3 3
Supervisor Code
1 1 1 1 1 6 6 2
User Codes
8 5
7
(3 WHEN
DURESS IS
ENABLED)**
8
7
(3 WHEN
DURESS IS
ENABLED)**
8 20 20 10 10 18
Total No. of Codes*
9 7 9
**
9 9
**
9 29 29 16 16 20
Duress Capability
ORDER DURESS
MODULE 6102-090
ORDER DURESS
MODULE 6102-090
ORDER DURESS
MODULE 6102-090
ORDER DURESS
MODULE 6102-090
ORDER DURESS
MODULE 6102-090
ORDER DURESS
MODULE 6102-090
ORDER DURESS
MODULE 6102-090
ORDER DURESS
MODULE 6102-090
✔
Time Delay
1-9 Min. 1-99 Min. 1-99 Min. 1-99 Min. 1-99 Min. 1-99 Min. 1-99 Min. 1-99 Min. 1-99 Min. 1-99 Min. 1-99 Min.
Time Delay Override
Code
✔ ✔ ✔ ✔ ✔ ✔
Time Lock (7-Day
Repeating Schedule)
✔
Penalty Lockout
Feature
✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔
Bolt Position Indicator
ORDER 6120-323 ORDER 6123-312 ORDER 6124-225 ORDER 6124-225 ORDER 6125-223 ORDER 6125-233 ORDER 6126-242 ORDER 6127-242 ORDER 6128-230 ORDER 6129-230
✔
Compatible with
Biometric Keypad***
✔ ✔
Locking Mechanism
MOTOR DRIVE MOTOR DRIVE MOTOR DRIVE MOTOR DRIVE MOTOR DRIVE MOTOR DRIVE MOTOR DRIVE MOTOR DRIVE MOTOR DRIVE MOTOR DRIVE MOTOR DRIVE
6120 SERIES
6123 SERIES
6124 SERIES IN
MULTI-USER MODE
6124 SERIES IN
DUAL USER MODE
6125 SERIES IN
MULTI-USER MODE
6125 SERIES IN
DUAL USER MODE
6126 SERIES
AUDIT LOCK
6127 SERIES
AUDIT LOCK
6128
A
-
series
™
6300 SERIES
6129
A
-
series
™
* Includes only codes that can be used to open the lock, but does not include special-purpose time delay override code(s) that may be available. Codes used only for programming and/or audit trail
management are not included in this number.
** If time delay override is not enabled, an additional user code is available, bringing the maximum number of user codes to 9 (8 codes are available if time delay override is enabled), with 3 of these
available when the duress function is enabled.