power consumption is rated in amps AC, simply multiply by the AC volts (115)
to determine the wattage.
Resistive loads are the easiest for the inverter to run; however, it will not run larger
resistive loads (such as electric stoves and heaters), which require far more
wattage than the inverter can deliver. Inductive loads (such as TVs and stereos)
require more current to operate than do resistive loads of the same wattage rating.
For safety reasons, the unit will simply shut down if it is overloaded. To restart
the unit, simply remove the load. Then plug devices back into the inverter
making certain that the total load does not exceed 16 watts continuous.
Protective Features
The inverter monitors the following conditions:
Low Battery Voltage – this condition is not harmful to the inverter but could
damage the powered device, so the inverter automatically shuts down when the
internal battery pack becomes low of charge. This will be indicated by a flashing
red LED in the front panel before automatic shutdown of inverter.
Thermal Shutdown Protection – the unit will automatically shut down when the
unit becomes overheated. Manual reset will be necessary after the unit cools
down to restart unit.
Overload/Short Circuit Protection –
the inverter will automatically shut down
when a short circuit occurs. Manual reset will be necessary to restart unit.
Note: The Bi-color Inverter Status LED Indicator will light red to indicate
Fault condition before automatic shutdown occurs.
OPERATING TIPS
The POWER TO GO
®
should only be operated in locations that are:
DRY – Do not allow water or other liquids to come into contact with the inverter.
COOL – Surrounding air temperature should be between –20°C and 40°C —
ideally between 15°C and 25°C (60 – 80°F). Keep the inverter away from direct
sunlight, when possible.
VENTILATED – Keep the area surrounding the inverter clear to ensure free air
circulation around the unit. Do not place items on or over the inverter during
operation. The unit will shut down if the internal temperature gets too hot. The
inverter will auto-reset after it cools down. Do not use inverter in a pocket.
SAFE – Do not use the inverter near flammable materials or in any locations that
may accumulate flammable fumes or gases. This is an electrical appliance that
can briefly spark when electrical connections are made or broken.