Burner Installation and adjustment
WARNING:
Adjusting the air-shutter while the grill is on operation. If it still hot, please wear protective gear and be careful. Failure to follow
this instruction could cause personal injury.
Flare-ups
“Flare-ups” sometimes occur when food drippings fall onto the hot heat distribution plate or burners and ignite. Some flaring is normal
and desirable as it helps impart the unique flavors associated with grilled foods. Controlling the intensity of the flare-ups is necessary,
however, in order to avoid burned or unevenly cooked foods and to prevent the possibility of accidental fire.
WARNING: Always monitor the grill closely when cooking and turn the flame level down to LOW or OFF if flare-ups
intensify.
Shutting Off Burners
1.
Always turn the valve knob(s) clockwise to the ‘’HIGH’’ position, and then press and turn
it to ‘’OFF’’. Never force the knob
without pressing it. This could damage the valve.
2.
Promptly turn
the gas supply to the “OFF” position at the propane cylinder.
3.
Close the lid of the grill.
Excess
flow
safety
valve
reset
procedure
The new regulators are equipped with a safety device that restricts the gas flow in the event of a gas leak. However, unsafe
practices of grill operation could activate the safety device without having a gas leak.
A sudden shut off of the gas flow typically occurs if you open the LP tank valve rapidly, or if one or more of the burner control
knobs is in an open position when opening the LP tank valve.
This procedure is effective with all LP Tank sizes as well as Natural Gas. When performing the procedure on a
Natural Gas model, simply substitute "Natural Gas valve" for "LP Tank".
To ensure the procedure is safely and successfully performed, please carefully follow these instructions:
1. Close the LP tank valve.
2. Turn all burner control knobs to the OFF position.
3. Disconnect the regulator from the LP tank.
4. Open the lid of the grill.
Normal: Soft blue flames with yellow tips
between I inch - 2 inches high.
Out of adjustment: Noisy hard blue
flames – too much air.
Poor combustion: Wavy, yellow
flames- too little air.
1. Release the screw on venturi tube.
2. Adjust the flame by turning the collar on head o
f
venturi tube from back side of the grill and do
not take apart the venturi tube.
3. Tighten the screw and make certain it is
secured.
1. Overlap 14 mm between
venturi tube and nozzle
when assembling.
2. Keep the center line of
venturi tube and nozzle on
one line.
1. Eng edge face upside for install the
burner.
Vue de la page 16