BW DEFENDER INTRODUCTION
The BW DEFENDER is designed for field friendly operation with large, bright, gas/
alarm indicators and one button operation. The BW DEFENDER provides effective
protection with the advantage of microcontroller based operation and the most
advanced sensing technology available.
! ADVANCED SENSING TECHNOLOGY: The NEW TWIN TOXIC sensor
employed in the BW DEFENDER has two separate chambers within one sensor
enclosure which provide independent gas sensing and signal outputs. This is not
to be confused with Dual Toxic sensors which are simply unfiltered carbon
monoxide sensors.
! BLACK & DECKER VERSAPAK™ VP100 BATTERY OPERATION: The NiCad
batteries are readily available in over 70 countries worldwide. VP100 batteries are
designed with zero memory cells for repetitive charging. Standard recharge time
with a VAC Charger is three hours. The batteries can be left in the VAC charger
(provided) without damage. VERSAPAK batteries have a minimum life of 300
charge cycles.
! MICROCONTROLLER BASED OPERATION: The BW DEFENDER is designed
with a microcontroller that ensures reliability. The advanced minicomputer in the
BW DEFENDER offers more built-in features and functions.
! LIQUID CRYSTAL DISPLAY: The extra-large LCD indicates the gas and
concentrations for 4 gases at one time. As well, it advises whenever the
BW DEFENDER is performing automatic functions. The graphic display icons
provide simple and clear alarm status advice.
! DISPLAY BACKLIGHTING: The backlight automatically activates whenever an
alarm condition exists. This feature can be accessed at any time with the touch of
a button to view the display in poor light.
BW DEFENDER MULTI-GAS DETECTOR comes complete with:
Wrist Strap
Black & Decker Two-Port 110 VAC Charger c/w Manual
2 VERSAPAK NiCad Batteries
Calibration Cup
BW DEFENDER Manual
Also available BW Defender Confined Space Kits
D4-CS-KIT BW Defender Confined Space Kit with Motorized Sampling Pump
D4-AS-KIT BW Defender Confined Space Kit with Aspirator Sampling Pump
Note 1: Order Number D4-2002-SP (Motorized Sampling Pump - included;
Calibration Cup - not included since not required).
Note 2: Order with the suffix “-A” to exclude the 2-port charger.
Note 3: Order with the suffix “-EU” for 230 VAC Charger - Continental European plug
Note 4: Order with the suffix “-UK” for 230 VAC Charger - UK/Ireland plug
CALIBRATION RECORDS
Date Calibrated Calibrated By
1 34
Updated May 30, 2000 English D1218-2.1 Page 1 (City Removed, -EU model added)
P34. English D1218/3: Nov/00 (model D4-2000-SP changed to D4-2002-SP)
Feb 12/01 (Note 3/4 “-EU,-UK”, Note 2,3 “models” to “order”)
Vue de la page 3