Black & Decker 200 WATT Guide de dépannage Page 1

Naviguer en ligne ou télécharger Guide de dépannage pour Adaptateurs et onduleurs de puissance Black & Decker 200 WATT. Black & Decker 200 WATT Troubleshooting guide Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 6
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
VEHICLE POWER SYSTEM
POWER INVERTER
200/400/750 WATT
VEC1045BD / VEC1046BD / VEC1047BD
USER’S MANUAL
& WARRANTY INFORMATION
TO REDUCE THE RISK OF INJURY, USER MUST READ AND UNDERSTAND
THIS INSTRUCTIONAL MANUAL. THIS MANUAL CONTAINS IMPORTANT
INFORMATION REGARDING THE OPERATION AND WARRANTY OF THIS
PRODUCT. PLEASE RETAIN FOR FUTURE REFERENCE.
www.vectormfg.com
8
Fault Protection Code and Troubleshooting Guide
INVERTER POWER SWITCH TURNED ON
SPECIFICATIONS
Power Inverter Model VEC1045BD VEC1046BD VEC1047BD
Maximum Continuous Power: 200 watts 400 watts 750 watts
Surge Capacity: 400 watts 800 watts 1500 watts
Input Voltage: 12.8 volts
Output Voltage: Approx. 115 volt AC RMS 60 Hz
Low Voltage Alarm: 11 volts DC ± 0.3 volt DC
Low Voltage Shutdown: 10.5 volts DC ± 0.3 volt DC
Thermal Shutdown: Automatic
Wave Form: Modified Sine Wave (MSW)
Output Connection: North American Standard Receptacles
Input Fuses: Internal
Input Cables: Battery cable with ring connector
Additional Protection: Overload, over voltage, overheating
Trouble/Indication Possible Cause Suggested Remedy
No AC output — DC input is out of range Check battery voltage.
(red LED lit
Excessive load — Turn unit off. Reduce the load,
thermal shutdown wait for the inverter to cool
down, then turn the unit on
again.
No AC output — Fuse(s) open Check DC input — fuse(s) in
green LED not lit vehicle. Replace the fuse with
one of the same type and rating
if necessary.
Low battery alarm Low battery voltage Recharge battery. Remove
sounds continuously load from the inverter while
recharging battery.
Bad connection or wiring Tighten all DC connections.
Motorized power tool Excessive start-up load If appliance does not start,
will not start appliance is drawing
excessive voltage and
will not work with inverter.
Motorized power tool Purely inductive load Make the load not purely
does not operate at inductive. Operate an
correct speed incandescent lamp at the
same time as motor.
Television/Radio Snow in picture, Keep inverter and antenna
interference “buzzing” sound distant from each other. Use
shielded antenna. Connect
antenna to amplifier.
VEC1045_46_47_BD_Manual 4/28/05 5:16 PM Page 8
Vue de la page 0
1 2 3 4 5 6

Résumé du contenu

Page 1 - POWER INVERTER

VEHICLE POWER SYSTEMPOWER INVERTER200/400/750 WATT VEC1045BD / VEC1046BD / VEC1047BDUSER’S MANUAL & WARRANTY INFORMATIONTO REDUCE THE RISK OF INJU

Page 2 - SAVE THESE INSTRUCTIONS

iiiImportant Cable InformationSubstantial power loss and reduced battery operating time results from inverters installed with cables thatare not able

Page 3 - TABLE OF CONTENTS

iv 1TABLE OF CONTENTSIntroduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1Features .

Page 4 - HOW THIS INVERTER WORKS

3The modified sine wave produced by the Power Inverter has an RMS (root meansquare) voltage of 115 volts, which is the same as standard household powe

Page 5

5Reverse polarity or short circuit condition may causeexternal or internal fuses to open and may cause irreversible damage to the PowerInverter. Take

Page 6 - TROUBLESHOOTING

7This problem does not occur with most battery-operated equipment.Most of these devices use a separate charger or transformer that isplugged into an A