9
The depth to which a fastener is driven is controlled by the depth adjustment knob (A)
Fig. 29. The depth of drive is factory adjusted to a nominal setting. Test fire a fastener
and check depth. If a change is desired, rotate the adjustment knob (A) Fig. 29. The
adjustment knob has detents every
1
/4 turn. Rotate the knob (A) Fig. 29 clockwise to
increase the depth of drive, rotate the knob counterclockwise to decrease the depth of
drive. Test fire another fastener and check depth. Repeat as necessary to achieve
desired results. The amount of air pressure required will vary depending on the size of
the fastener and the material being fastened. Experiment with the air pressure setting to
determine the lowest setting that will consistently perform the job at hand. Air pressure
in excess of that required can cause premature wear and/or damage to the tool.
Fig. 29
Fig. 30
A
A
RUBBER NOSE CUSHION
A rubber nose cushion (A) Fig. 30 is provided to reduce marring of the work surface.
The rubber cushion can be removed, and stored inside the magazine (B) Fig. 31 when
it is not required.
Disconnect tool from air supply before removing or re- installing rubber
cushion.
CLEARING A JAMMED FASTENER
Disconnect tool from air supply.
1. Open magazine and remove remaining fasteners. (Fig. 32 and Fig. 33)
Remove fasteners from tool before opening the fastener guide
plate. Fasteners are under pressure and may shoot out of magazine which could
cause injury.
2. Open the quick release latch and the fastener guide plate. (Fig. 34)
3. Remove the jammed fastener. (Fig. 35)
4. Close the fastener guide plate, and the quick release latch.
Fig. 31