Black & Decker MULTI-GAS DETECTORS Manuel d'utilisateur Page 6

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 6
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 5
GasAlertMax
H
2
S, CO, O
2
and LEL
Multi-Gas Detector with
Internal Sampling Pump
RATINGS AND CERTIFICATIONS:
(Intrinsic safety)
ed to US and Canadian
Standards by CSA:
Class I, Div. 1, Groups A, B, C, D
Class I, Zone 0, Gr. IIC
ATEX Certfied by LCIE
CE g II 2 G
EEx ia d IIC
CE Declared for European Conformity
Combustible Gas Performance
Certifi ed to:
ANSI/ISA-S12.13
CSA C22.2 No. 152
EMI/RFI:
Complies with EMC Directive 89/336/EEC
BW1009-01-01-00-8.25x11-5123-3
Classif
Australia: Ex ia s IIB
For further information:
1-888-749-8878 USA
1-800-663-4164 Canada
+44 (0) 1869 233004 Europe
+971-4-8871766 Middle East
+61-7-3818-8244 Australia
+1-403-248-9226 other countries
Corporate Headquarters
2840 - 2 Avenue S.E.
Calgary, AB, Canada T2A 7X9
Fax: +1-403-273-3708
www.gasmonitors.com
SPECIFICATIONS
D
ETECTOR: 2, 3 and 4-gas detectors
Gas: H
2
S
CO
O
2 (% by vol.)
Combustibles
Measuring Range: 0 - 100 ppm 0 - 500 ppm 0 - 30.0% 0 - 100% LEL
Low Alarm Level
1
: 10 ppm 35 ppm 19.5% 10%
TWA alarm level
1
: 10 ppm 35 ppm N/A N/A
High alarm level
1
: 15 ppm 200 ppm 23.5% 20%
Auto Zero: Yes
Calibration: Automatic
Backlight: Low light (auto) alarm conditions (auto) and on demand
Full function self-test: Verifi es: integrity of sensor, battery and circuitry; audible/visual alarms
Sensor: Plug-in, electrochemical cells (H
2
S/CO TWIN TOX, O
2
); catalytic bead (LEL)
Sampling pump: 250 ml/min
User fi eld options: Confi dence Beep, Pass Code Protection, Latching Alarms, Sensor Disable.
-DL2 models only: fi eld-settable real-time clock and calender
INDICATORS AND ALARMS: Clearly advises alarm levels both visually and audibly
Visual gas alarm: Flashing, wide-angled alarm lens with dual red LEDs plus alarm LCD readout
Audible gas alarm: High-output, variable, pulsing siren 95 dB at 1 ft. (0.3 m)
Other: Low battery, Off warning, Sensor fail, Multiple gas hazard, Data card fail
Remote jack: Accepts vibrating alarm, or remote audible/visual alarm (110 dB) or earphone
LCD DISPLAY: Continuous, alphanumeric gas readout and status display:
Gases monitored: H
2
S, CO, O
2
and LEL
Gas ppm or %: Simultaneously and continuously displays gas concentrations present
TWA ppm or %: Records and displays TWA exposure(s) on demand
Peak ppm or %: Records and displays peak exposure to gas and on demand
Setpoints: Displayed on activation (auto) and on demand in ppm or %
TESTS:
Self-test: Full function self-test on activation (auto)
Battery: Continuous (auto)
GENERAL SPECIFICATIONS: Shock-resistant ABS enclosure
Operating temperature: -20 to +50°C (-4 to +122°F)
Humidity: 5% to 95% RH (non-condensing)
Battery: One 3.6 volt Black & Decker VersaPak
TM
rechargeable cell
Battery life: NiMH up to 12 hours operation; NiCd up to 8 hours operation
Size: 1.6 x 3.0 x 5.9 inches (40 x 75 x 150 mm)
Weight: 15.4 oz. (396 g)
WARRANTY: 2 years including sensors
DATALOGGER OPTIONS:
Data recorded: All events and occurrences
Sampling rate: One reading every 5 seconds (standard)
Storage: Over 4 months (based on a normal workweek). Scalable up to one year.
32 MB Flash MMC (MultiMediaCard) standard
1
Alarm levels are fi eld-settable. Factory defaults are shown are for US and Canada. Defaults will vary by country and region.
HIGH alarm takes precedence over TWA alarm. TWA alarm takes precedence over LOW alarm.
DUE TO ONGOING RESEARCH AND PRODUCT IMPROVEMENT, SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.
Ordering Information: GasAlertMax is delivered complete, ready for use with
sensors, internal sampling pump, datalogger, BLACK & DECKER 110 VAC 2-port charger, two VERSAPAK™ batteries,
10 ft. (3 m) sampling hose, carrying holster, cal hose, fi lter kit and instructions in local languages.
Gas Detectors (Standard)
GAMAX3-4 4-gas: H
2
S, CO, O
2
, LEL
GAMAX3-3H 3-gas: H
2
S, O
2
, LEL
GAMAX3-2 2-gas: O
2
, LEL
Gas Detectors with Black Box Datalogger
GAMAX3-4-DL1 4-gas detector
GAMAX3-3H-DL1 3-gas detector
GAMAX3-2-DL1 2-gas detector
Gas Detectors with User Downloadable Datalogger
Comes c/w free software and 32 MB MMC Card
GAMAX3-4-DL2 4-gas detector
GAMAX3-3H-DL2 3-gas detector
GAMAX3-2-DL2 2-gas detector
Add suffi x for delivery with 230 VAC charger
Add suffi x: -EU (European version)
-UK (United Kingdom version)
-AU (Australian version)
-NZ (New Zealand version)
-OR (Other Regions)
Add suffi x: -A (to omit VAC charger and batteries)
Calibration Equipment
Kits come complete with regulator, cal hose in carrying case
For 4 and 3-gas detectors (LEL, O
2
, H
2
S, CO)
CK-Q34 4-gas kit with 34L cylinder
CK-Q58 4-gas kit with 58L cylinder
CG-Q34 Quad gas 34L cylinder
CG-Q58 Quad gas 58L cylinder
CG-BUMP1 Alarm test gas 11L
REG-0.5 0.5 LPM Regulator included in kits
For 2-gas detectors (%LEL, O
2
)
CK-T34 2-gas kit with 34L cylinder
CG-T34 2-gas 34L cylinder
REG2-0.5 Regulator included in 2-gas kits
Sensor Replacements
D4-RW90 Combustible (0-100% LEL)
SR-X10 Oxygen (O
2
)
D4-RHM04 TWIN TOX (CO, H
2
S)
PS-RH04S H
2
S (-3H versions)
Locally Distributed By:
Vue de la page 5
1 2 3 4 5 6

Commentaires sur ces manuels

Pas de commentaire