The compact, lightweight GasAlertMax fi ts in the palm of your
hand. The intuitive detector is designed with automatic features and
functions.
- Larger, User-Friendly LCD -
GasAlertMax is equipped with a high-defi nition LCD. The display
shows all current conditions and advises the user when automatic
functions are taking place. The alphanumeric LCD keeps you advised
of any gas hazard present. The backlight illuminates automatically
in low light conditions and in all alarm conditions. The backlight also
activates on demand.
- Audible/Visual Gas Alarms -
Audible (95 dB) alarms and visual alarms activate, ensuring
maximum protection. Visual alarms feature the unique wide-
angled alarm bar and fl ashing screen icons that advise alarm
level and type (LOW - TWA - HIGH - Multiple Gas). The LCD
g
as icon fl ashes to advises which
g
as hazard is present.
In Low Alarm, the audible
alarm sounds in a slow
repeating pattern and the
visual alarm LEDs fl ash in
sync.
TWA (Time Weighted
Average) and High Alarm
conditions feature urgent,
rapid audible/visual patterns.
Alarm levels are fi eld-settable.
- Auto ON Functions -
GasAlertMax tests all features and functions each time it is turned on,
ensuring the instrument is ready for use.
The sensors, battery and data card are tested.
The oxygen sensor is calibrated
automatically.
Current alarm setpoints are displayed.
All display elements, the backlight
and audible/visual alarms are
activated.
Current time, day and date are
displayed on user-downloadable
datalogger models (-DL2).
- Automatic Sensor Calibration -
Auto zero the sensors, at any time, without
calibration gas. Calibrate one or all four
sensors automatically. Simply apply gas when
the fl ashing Auto Span icon lights.
GasAlertMax tests the calibration gas applied.
If the calibration gas does not meet expected
parameters, the instrument exits Calibration
Mode to prevent improper calibration. All the
previous calibration data is retained.
- High-Effi ciency Sampling Pump -
GasAlertMax is equipped with a high-effi ciency, motorized sampling
pump. The rotary vane design provides the benefi ts of a small turbine
- greater reliability with less friction - and the pump is not pressure
sensitive. The detector will automatically advise if the pump or
sampling hose is blocked.
Status at a Glance: Information and guidance is
provided clearly and quickly by the GasAlertMax:
- Lower Capital, Training, Maintenance Costs -
As we all know, cell phones, computers and palm pilots
have become smaller, smarter and more affordable. BW
Technologies has introduced the same technological advances
into the GasAlertMax. Cutting-edge technology in sensors,
microcontrollers, program features and fi ber optics result in a
more compact, affordable and easy-to-use safety instrument.
Two (2) levels of alarm for each gas sensed.
Low battery warning provides a 30-minute alert.
GasAlertMax cannot be accidentally shut off.
Missing sensor alarm advises which sensor is missing.
LEL sensor over range alarm protection.
Gas alarms take priority over all other alarms.
2-year warranty on all sensors.
Alarm Advice: The alarm icons will
light to advise the gas level and alarm
type encountered: LOW, HIGH or TWA
gas alarms.
A TWA alarm overrides a LOW alarm,
and a HIGH alarm overrides a TWA
alarm.
Battery Level: The battery condition is
continuously tested and displayed.
Datalogging Advice: The data card
icon lights if the data card is present
and functioning.
Auto Pump Re-Calibration: Sampling
pump calibration is automatic.
- Additional Features and Functions -
- User Field Options -
Select any or all of the following:
Confi dence Beep - the detector beeps
every 5 seconds when selected on start-up.
Pass Code Protection - restricts
access to calibration and alarm
setpoints functions.
Latched Gas Alarms - Audible/
Visual Alarms will continue to sound
until the alarm is acknowledged.
Change Time and Date - change the time and date on
user-downloadable detectors (-DL2) in the fi eld if required.
- Field Upgrade -
If requirements change, 2 and 3-gas detectors can be upgraded
in the fi eld to a 3 and/or 4-gas detector by adding a sensor.
Vue de la page 2
1 2 3 4 5 6

Commentaires sur ces manuels

Pas de commentaire

Premier Mounts Televisori e monitor manuali utente

La lista di Premier Mounts Televisori e monitor prodotti contiene 1 manuali utenti per 1 modelli. Tutte le guide utenti pdf sono disponibili per essere scaricate o visionate online.

Cliccare su un alfabeto di seguito per far scorrere la lista completa dei modellif models starting with that letter

Modelli Tipo di Documento