BW Defender2
User Manual
30
Setting the High Alarm Setpoint
The display shows the High Alarm setpoint for H
2
S:
The Set up/down arrows lights, prompting you to input a new
High Alarm setpoint.
4. To change the High Alarm setpoint for this sensor, press
G or H until the display shows the new value.
5. Press to save the displayed value.
Note
If you do not press any pushbuttons within 10
seconds, the detector automatically retains the High
Alarm setpoint.
If you change a High Alarm setpoint but pause for
10 seconds before pressing , the detector rejects
the new value. The display shows no and the
audible alarm beeps six times. The display then
shows the unchanged High Alarm setpoint.