Black & Decker MULTI-GAS DETECTORS Manuel d'utilisateur Page 33

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 71
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 32
BW Defender2
User Manual
22
Resetting Gas Alarm Setpoints
Note: Standard factory alarm setpoints may vary by region.
Table 9. Factory Set Alarm Setpoints
Gas Low High
CO 35 ppm
(parts per million)
200 ppm
H
2
S 10 ppm 15 ppm
O
2
19.5% 23.5%
Combustible
Gases
10% LEL 20% LEL
To change the factory-set alarm setpoints, refer to the section
“Calibration and Setting Alarm Setpoints.
You can disable an alarm by setting the alarm setpoint to 0.
Setting the Low Alarm setpoint to 0 turns off the Low and
TWA Alarms.
The detector allows you to set the O
2
alarm setpoints for Low
Alarm above or below 20.9% and to set High Alarm above or
below 20.9% as desired.
Stopping a Gas Alarm
The Low and High Alarms stop when the ambient gas level
returns to the acceptable range.
Note
If alarms are set to latch, press to reset the
audible and visual alarms.
The detector computes the TWA value based on an 8-hour
workday. Only deactivating the detector can stop the TWA
Alarm.
Vue de la page 32
1 2 ... 28 29 30 31 32 33 34 35 36 37 38 ... 70 71

Commentaires sur ces manuels

Pas de commentaire