BW Defender2
User Manual
14
Confidence Beep
The Confidence Beep tells you the Detector is ON and the
battery has sufficient power respond to a hazardous level of
gas and emit an alarm. Instead of beeping when the battery’s
power is low, the audible alarm beeps to advise you the
battery has sufficient power. The Confidence Beep stops
when the battery power is low.
You can only activate the Confidence Beep at startup.
To turn on the Confidence Beep:
1. If the detector is on, deactivate the detector.
2. Press A and simultaneously.
After the self-test completes, the detector continuously beeps
once every 5 seconds.
To turn off the Confidence Beep, turn off, and then
restart the detector.
User Option Menu
User options are:
1. Finish options and exit User Options Menu.
2. Set latching alarm function
3. User Downloadable Datalogger model only:
Adjust real-time clock and calendar.
4. Enable or disable operation of one or more
sensors.
5. Enable or disable Pass Code Protection.
To access the User Options press
G and H simultaneously until the
display reads:
To choose the desired options
press H or G. Press
to select the option.
To exit the options menu and return
to normal operation at any time,
press when the display
shows Finish Options.
For options 4 and 5, see "User Options" (P. 40).