Black & Decker MULTI-GAS DETECTORS Manuel d'utilisateur Page 68

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 72
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 67
GasAlertMax
User Manual
O
2
measuring principle: Capillary controlled concentration
sensor
Pump flow rate: 250 ml/min. (minimum)
Detection techniques:
H
2
S and CO: TWA, STEL, low, and high alarms
O
2
and LEL: Low and high alarms
Alarm conditions: TWA alarm, STEL alarm, low alarm, high
alarm, multi-gas alarm, sensor alarm, pump alarm, low
battery alarm, confidence beep, automatic shutdown alarm.
Audible alarm: 95 dB at 1 ft (0.3 m) variable pulsed beeper
Visual alarm: Red light-emitting diode (LED)
Display: Alphanumeric liquid crystal display (LCD)
Backlight: Automatically activates whenever there is
insufficient light to view the LCD and during alarm conditions.
Self-test: Initiated at activation
Calibration:
Automatic zero and automatic span
Oxygen sensor: on activation (if enabled in the user options
menu)
User enable/disable options:
Confidence beep, latching alarm, pass code protect,
automatic O
2
calibration at startup, automatic pump test at
startup (supplied by manufacturer with these options
disabled); set calibration due date; set STEL calculation
period, set span concentration values, adjust clock calendar,
language selection, and sensor disable.
Approved batteries:
Black & Decker VersaPak™ NiCd (VP-100) rechargeable
battery
Black & Decker VersaPak™ NiMH (VP-110) rechargeable
battery
Area NiCd (VP-100) NiMH (VP-110)
North America T4 (131.6°C) T4 (134.6°C)
Europe T4 T3 (184°C)
Battery charger: Black & Decker VersaPak™ VP130
charger
Battery operating time:
NiCd: 8 hours
NiMH: 10 hours
58