GasAlertMax
Calibration and Setting Alarm Setpoints
Calibrate only in a clean atmosphere, which is free of
background gas.
To disable an alarm, set its alarm setpoint to 0.
The LEL sensor is factory calibrated to methane. If
monitoring a different combustible gas, calibrate the
sensor using the appropriate gas.
The oxygen sensor can be automatically calibrated on
activation if this feature is enabled. Activate detector in a
normal (20.9% O
2
) atmosphere.
If you require a certified calibration, contact
BW
Technologies.
High CO concentrations above the top of the measuring
range are not indicated as OL (transgression of the
measuring range). If the end of the measuring range is
exceeded, the function of the apparatus has to be
checked with test gas.
CO measuring values from –3 ppm (v/v) up to +3 ppm
(v/v) and H
2
S measuring values from –1 ppm (v/v) up to
+1 ppm (v/v) are indicated during measuring operation
as 0 ppm (v/v).
The cross sensitivities described in the sensor
datasheet are to be considered. Due to sensor cross
sensitivities, H
2
S concentrations within the measuring
range can cause a CO indication.
H
2
S concentrations within the measuring range can
cause an adverse effect on the catalytic LEL sensor.
After an H
2
S alarm, it is necessary to check the
measuring function of the LEL sensor.
Note
The detector must be calibrated if a negative
measuring value is indicated during operation.
33