GasAlertMax
Alarms
Gas Alarm Setpoints
The detector's gas alarm setpoints trigger the gas alarms
described in the table below.
Table 8. Gas Alarm Setpoints
Alarm Condition
Low alarm CO, H
2
S, and LEL: Ambient
gas level above low alarm
setpoint. (For O
2
,
Oxygen
Alarm Setpoints)
High alarm CO, H
2
S, and LEL: Ambient
gas level above high alarm
setpoint. (For O
2
, see Oxygen
Alarm Setpoints.)
TWA alarm
(CO and H
2
S
only)
Accumulated value above the
TWA alarm setpoint.
STEL alarm
(CO and H
2
S
only)
Accumulated value above the
STEL alarm setpoint.
Multi-gas alarm Two or more gas alarm
conditions.
Oxygen Alarm Setpoints
User selectable for low and high alarms in the 0-30.0%**
range. Set both below, both above, or one above and one
below 20.9% as desired.
Alarm setpoints > 20.9% (v/v) for increasing oxygen
concentrations.
Alarm setpoints < 20.9% (v/v) for decreasing oxygen
concentrations.
** Refer to Specifications
Resetting Gas Alarm Setpoints
Note
Standard factory alarm setpoints may vary by
region.
Table 9. Factory Set Alarm Setpoints
Gas Low High TWA STEL
CO 35 ppm 200 ppm 35 ppm 50 ppm
H
2
S 10 ppm 15 ppm 10 ppm 15 ppm
O
2
19.5% vol 22% vol N/A N/A
Combustible
Gases
10% LEL 20% LEL N/A N/A
29