GasAlertMax
Confidence Beep
Confidence Beep
The confidence beep notifies that the detector is activated
and the battery has sufficient power to respond to a
hazardous level of gas and emit an alarm. Instead of beeping
when the battery power is low, the audible alarm beeps to
advise that the battery has sufficient power. The confidence
beep stops when the battery power is low.
The confidence beep can only be enabled at start-up
To activate the confidence beep:
1. If the detector is activated, deactivate the detector.
2. Press and hold C then press F at each start-up.
After the self-test completes, the detector continuously beeps
once every 5 seconds.
User Options Menu
The following are the available user options:
1. FiniSh OptionS: Exits the user options menu
2. AdJuSt Clock: Adjust real-time clock and calendar;
3. toggLE H2S SEn: Enable/disable H
2
S sensors;
4. toggLE CO SEn: Enable/disable CO sensors;
5. toggLE LEL SEn: Enable/disable LEL sensors;
6. toggLE O2 SEn: Enable/disable O
2
sensors;
7. PASS Lock: Enable/disable pass code protection;
8. LAtch in ALArmS: Enable/disable latching alarm;
9. toggLE 02 CAL: Enable/disable automatic oxygen
calibration at start-up;
10. SEt CAL SPANS: Set calibration gas span
concentration values;
11. toggLE PumPtSt: Enable/disable pump test at start-up;
12. StEL Period: Set STEL calculation period;
13. AnZEIgE dEutSCH: Select German language.
15